TM 10-3930-669-34
(3)
Loosen bezel lock.
(4)
Turn bezel until zero is aligned with pointer.
Tighten bezel lock.
(5)
Place mark (15) on pulley (7) at the point indicated by the pointer.
(6)
Using retainer, turn pulley (7) to the right one half rotation.
(7)
Using retainer, turn pulley (7) to the left until the dial gauge pointer begins to move.
3-13
|