TM 10-3930-669-20 NOTE Note position of fittings prior to removal. (12) Remove fitting (28), seal (29), and washer (30) from heater valve (14). Discard seal. (13) Remove fitting (31) from fitting (32). (14) Remove fitting (32) from fitting (33). (15) Remove fitting (33), seal (34), and washer (35) from heater valve (14). Discard seal. (16) Remove heater valve (14) and gasket (36) from oil filter hose adapter (37).  Discard gasket. (17) Remove oil hose adapter (37) from soft-jawed vise. b.  Cleaning/Inspection. WARNING · Drycleaning solvent (P-D-680) is TOXIC and flammable.  Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors.  Keep away from heat or flame.  Never smoke when using solvent; the flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. · If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.  If solvent contacts skin or clothes, flush with cold water.  If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. (1) Clean all metal parts with drycleaning solvent. (2) Inspect all parts for breaks, cracks, burrs, and sharp edges. (3) Replace all damaged parts. 16-35