TM 10-3930-669-20
(3) Remove nut (29), lock washer (30), and link
assembly (24) from pivot assembly (31). Discard
lock washer.
(4) Remove two screws (32), lock washers (33), and
pivot assembly (31) from motor mount (28).
Discard lock washers.
c. Cleaning/lnspection.
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not
breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C). Failure
to do so may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
(1) Clean all metal parts with drycleaning solvent.
(2) Inspect all parts for breaks, cracks, burrs, and sharp edges.
(3) Replace all damaged parts.
d. Assembly.
(1) Install pivot assembly (31) on motor mount (28) with two screws (32) and lock washers (33).
(2) Install link assembly (24) on pivot assembly (31) with nut (29) and lock washer (30). Tighten nut to 56 lb-in (6
Nm).
16-9
|