| |
TM 10-3930-669-20
15-19. MAST LEVEL INDICATOR REPLACEMENT/ADJUSTMENT (CONT).
b. Cleaning/lnspection.
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles
and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes; and do not breathe vapors. Keep away from heat or flame. Never smoke
when using solvent; the flashpoint for type I drycleaning solvent is 100°F (38°C)
and for type II is 138°F (50°C). Failure to do so may result in injury or death to
personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air
and medical help. If solvent contacts skin or clothes, flush with cold water. If
solvent contacts eyes, immediately flush eyes with water and get immediate
medical attention.
(1)
Clean all metal parts with drycleaning solvent.
(2)
Inspect all parts for breaks, cracks, burrs, and sharp edges.
(3)
Inspect indicator for straightness.
(4)
Inspect screws for signs of damage.
(5)
Replace all damaged parts.
c. Installation. Install indicator (3) on mast (4)
with two washers (2), and screws (1). Do not
tighten screws.
15-72
|