TM 10-3930-669-20
15-17. CAB INSULATION REPLACEMENT (CONT).
b. Installation.
WARNING
Adhesive causes immediate bonding on contact with eyes, skin, or clothing and also
gives off harmful vapors. Wear protective goggles and use in well-ventilated area. If
adhesive gets in eyes, try to keep eyes open; flush eyes with water for 15 minutes and
get immediate medical attention.
CAUTION
· Use proper adhesive on all panels that are used inside the cab. Using wrong
adhesive will cause premature failure.
· Ensure that cab surface is free of old adhesive, insulation, dirt, and grease. Dirty
surface will cause premature failure.
NOTE
· Ensure that insulation
panels meet specifications
of drawings in Step c.
· Ensure that insulation
panel fits section of cab to
be covered.
· Ensure that adhesive is
applied to side of
insulation panel that
contacts cab surface.
· Cab wall installation
procedure is shown.
Installation procedures
for cab roof and cab door
are similar.
(1)
Coat insulation (1) with adhesive.
(2)
Position insulation (1) on cab wall (2).
(3)
Press insulation (1) uniformly over
entire surface.
(4)
Press top edge of insulation (1) under
metal trim edge of cab wall (2).
15-60
|