TM 10-3930-669-20 15-15.  BATTERY BOX REPLACEMENT (CONT). b.  Cleaning/Inspection. WARNING ·    Drycleaning solvent (P-D-680) is TOXIC and flammable.  Wear protective goggles and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe vapors.  Keep away from heat or flame.  Never smoke when using solvent; the flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. ·    If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical help.  If solvent contacts skin or clothes, flush with cold water.  If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. (1) Clean all metal parts with drycleaning solvent. (2) Inspect battery hold down clamp for cracks or damage. (3) Clean battery box with wiping cloths and detergent. (4) Neutralize battery acid on battery box with baking soda. (5) Inspect battery box for cracks or breaks. (6) Replace damaged parts or notify supervisor. c.  Installation. (1) Install battery box (20) on forklift (24) with five lock washers (23) and screws (22). (2) Install two studs (21) on battery box (20). (3) Install two batteries (19) in battery box (20). (4) Install battery hold down clamp (18) and secure with two washers (17) and nuts (16). 15-50