TM 10-3930-669-20
(3)
Lift red rubber terminal cover (9) and
loosen nut (10) until positive side of
cable (7) can be removed from positive
battery terminal (11).
(4)
Lift red rubber terminal cover (12) and
loosen nut (13) until positive cable (14)
can be removed from positive battery
terminal (15).
WARNING
· Battery acid (electrolyte) is extremely harmful. Always wear safety goggles and
rubber gloves, and do not smoke when preforming maintenance on batteries.
Injury will result if acid contacts skin or eyes. Wear rubber apron to prevent
clothing being damaged.
· Remove all jewelry such as rings, dogs tags, bracelets, etc. If jewelry contacts
battery terminal, a direct short may result in instant heating of tools, damage to
equipment, and injury or death to personnel.
(5)
Remove two nuts (16) washers (17), and
battery hold down clamp (18).
(6)
Remove two batteries (19) from battery
box (20).
(7)
Remove two studs (21) from battery
box (20).
(8)
Remove five screws (22), lock
washer (23), and battery box (20)
from forklift (24). Discard lock washer.
15-49
|