TM 10-3930-669-20
(2)
Assembly.
(a) Strip end of wire (5) leaving 1/4 in. (0.64
cm) of bare wire.
NOTE
Wire should be positioned so larger
wings of terminal will crimp around
insulation and smaller wings will
crimp around exposed bare wire.
(b) Push terminal (3) open and position wire
(5).
(c) Crimp terminal (3) on wire (5).
(d) Install conduit (4) on wire (5).
(e) Install terminal (3) in connector (1).
(f)
Connect front worklight connector (2) on
connector (1).
c.
Type III Connector Repair.
(1)
Disassembly.
(a) Disconnect connector (1).
(b) Using
terminal
removal
tool,
remove
terminal (2) from connector (1).
(c) Cut and remove terminal (2) from wire (3).
7-136
|