7-54. GENERAL CONNECTOR REPAIR (CONT).
(2)
Assembly.
(a) Strip end of wire (3) leaving 1/4 in. (0.64
cm) of bare wire.
NOTE
Wire should be positioned so larger
wings of terminal will crimp around
insulation and smaller wings will
crimp around exposed bare wire.
(b) Push terminal (2) open and position wire
(3).
(c) Crimp terminal (2) on wire (3).
(d) Install terminal (2) in connector (1).
(e) Connect connector (1).
b.
Type II Connector Repair.
(1)
Disassembly.
(a)
Disconnect connector (1) from front worklight connector (2).
(b)
Using terminal removal tool, remove terminal (3) from connector (1).
(c)
Remove conduit (4) from wire (5).
(d)
Cut and remove terminal (3) from wire (5).
7-135
|