TM 10-3930-669-20
(3)
Lift red rubber terminal cover (9) and
loosen nut (10), until positive side of
cable (7) can be removed from
positive battery terminal (11).
(4)
Lift red rubber terminal cover (12) and
loosen nut (13) until positive cable
(14) can be removed from positive
battery terminal (15).
b.
Cleaning/Inspection.
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective
goggles and gloves; use only in a well-ventilated area; avoid contact with
skin, eyes, and clothes; and do not breathe vapors. Keep away from heat or
flame. Never smoke when using solvent; the flashpoint for type I
drycleaning solvent is 100'F (38'C) and for type II is 138'F (50'C). Failure to
do so may result in injury or death to personnel.
If personnel become dizzy whil e using cleaning solvent, immediately get
fresh air and medical help. If solvent contacts skin or clothes, flush with
cold water. If solvent contacts eyes, immediately flush eyes with water and
get immediate medical attention.
Battery acid (electrolyte) is extremely harmful. Always wear safety goggles
and rubber gloves, and do not smoke when performing maintenance on
batteries. Injury will result if acid contacts skin or eyes. Wear rubber apron
to prevent clothing being damaged.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry
contacts battery terminal, a direct short may result in instant heating of
tools, damage to equipment, and injury or death to personnel.
(1)
Neutralize battery acid on cables and battery with baking soda or household ammonia solution.
(2)
Clean all metal parts with drycleaning solvent.
(3)
Clean battery surface with wiping cloths and detergent.
(4)
Clean wire and cable metal ends and battery terminals with a wire brush.
(5)
Inspect cables for cracks or damage.
(6)
Replace damaged parts or notify supervisor.
7-113
|