TM 10-3930-669-20 7-47.  BATTERY REPLACEMENT (CONT). b. Cleaning/Inspection. WARNING Drycleaning  solvent  (P-D-680)  is  TOXIC  and  flammable.    Wear  protective goggles  and  gloves;  use  only  in  a  well-ventilated  area;  avoid  contact  with skin, eyes, and clothes; and do not breathe vapors.  Keep away from heat or flame.        Never    smoke    when    using    solvent;    the    flashpoint    for    type    I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).  Failure to do so may result in injury or death to personnel. If  personnel  become  dizzy  while  using  cleaning  solvent,  immediately  get fresh  air  and  medical  help.    If  solvent  contacts  skin  or  clothes,  flush  with cold water.  If solvent contacts eyes, immediately flush eyes with water and get immediate medical attention. (1) Clean all metal parts with drycleaning solvent. (2) Inspect battery hold down clamp for cracks or damage. (3) Clean battery box with wiping cloths and detergent. (4) Neutralize battery acid on battery box with baking soda. (5) Inspect battery box for cracks or breaks. (6) Replace damaged parts or notify supervisor. c. Installation. (1) Install  two  studs  (21)  on  battery  box (20). (2) Install two batteries (19) in battery box (20). (3) Install  battery  hold  down  clamp  (18) and secure with two washers (17) and nuts (16). 7-108