TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
VOLTAGE TEST
(1) Set multimeter select switch to
VOLTS DC.
(2) Connect positive (+) multimeter
lead to main power switch, output
terminal.
(3) Connect negative (-) multimeter
lead to a known good ground.
(4) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, perform Step (5) below
and replace main power switch
(Para 7-15).
(b) If there are 22 to 24 vdc
present, main power switch is
OK.
(5) Set MAIN POWER switch to OFF
position.
(6) Close engine access panel
(TM 10-3930-669-10).
2-33
|