TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
VOLTAGE TEST
(1) Set multimeter select switch to
VOLTS DC.
(2) Connect positive (+) multimeter
lead to relay R5, terminal 30
cavity.
(3) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(4) Connect negative (-) multimeter
lead to a known good ground.
(a) If there are not 22 to 24 vdc
present, perform Step (5) below
and repair wire 7 (see schematic
Appendix F).
(b) If there are 22 to 24 vdc
present, wire 7 is OK.
(5) Set MAIN POWER switch to OFF
position.
CONTINUITY TEST
(1) Set multimeter select switch to
OHMS.
(2) Check continuity between relay R5,
terminal 87 cavity and starter
solenoid wire 23 terminal.
(a) If there is no continuity, repair
wire 23 (see schematic
Appendix F).
(b) If there is continuity, replace
relay R5 (Para 7-33).
(3) Install relay R5 (Para 7-33).
2-27
|