TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
VOLTAGE TEST
(1) Remove relay R5 (Para 7-33).
(2) Set multimeter select switch to
VOLTS DC.
(3) Connect positive (+) multimeter
lead to relay R5, terminal 86
cavity.
(4) Connect negative (-) multimeter
lead to a known good ground.
(5) Start engine (TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, perform Steps (6) and
(7) below and go to Step 11 of
this Fault.
(b) If there are 22 to 24 vdc
present, perform Step (6) below
and go to Step 8 of this Fault.
(6) Shut down engine.
(7) Install relay R5.
CONTINUITY TEST
(1) Set multimeter select switch to
OHMS.
(2) Check continuity between relay R5,
terminal 85 cavity and a known
good ground.
(a) If there is no continuity, repair
relay R5 ground wire 5 (see
schematic Appendix F).
(b) If there is continuity, relay R5
ground wire is OK.
2-25
|