TM 10-3930-669-20
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and
do not breathe vapors. Keep away from heat or flame. Never smoke when using solvent;
the flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).
Failure to do so may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent
contacts eyes, immediately flush eyes with water and get immediate medical attention.
CAUTION
Area around filter must be very clean. Any contaminants entering filter adapter will damage
equipment.
(2)
Using wiping rags, clean area around fuel
filter (1).
(3)
Remove fuel filter (1) and preformed
packing (2) from fuel filter head (3).
Discard filter and preformed packing.
NOTE
Tag and mark fuel hoses prior to
removal.
(4)
Remove two screws (4), four washers (5),
and two fuel hose (6) from fuel filter head
(3).
(5)
Remove two nuts (7), washers (8), screws
(9) and fuel filter head (3) from filter tray
(10).
4-25
|