TM 10-3930-669-20
(8)
Remove
three
grommets
(20)
and
grommet (21) from fuel pipe assembly
(17).
(9)
Remove two nuts (22), lock washers (23),
screws (24), and clamps (25) from fuel
pipe
assembly
(17).
Discard
lock
washers.
(10)
Remove rubber seal (26) from fuel pipe
assembly (17).
b.
Cleaning/Inspection.
WARNING
Dry-cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe
vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type
I dry-cleaning solvent is 100°F (38°C) and for type II is 138°F (50°C). Failure to do so may result
in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
Compressed air used for cleaning purposes will not exceed 30 psi (207 kPa). Use only with
effective chip guarding and personal protective equipment (goggles/shield, gloves, etc.).
(1)
Clean all fittings and lines (exterior) with clean cloth moistened with dry-cleaning solvent.
(2)
Introduce 25 to 30 psi (172 - 206 kpa) of dry air into lines to clear any foreign matter.
(3)
Inspect lines for cracks, chafing, and defective connectors. Replace if defective.
(4)
Inspect fittings for cracks and thread distortions. Replace if defective.
4-13
|