4-4. AIR CLEANER ASSEMBLY REPLACEMENT/REPAIR (CONT).
b.
Disassembly.
(1)
Remove two screws (16) and nuts (17)
from straps (18).
(2)
Pull air cleaner housing (4) from straps
(18).
(3)
Remove four nuts (19), screws (20),
washers (21), and two straps (18) from
bracket (22).
c.
Assembly.
(1)
Install two straps (18) on bracket (22) with
four washers (21), screws (20), and nuts
(19).
(2)
Position air cleaner housing (4) in straps
(18).
(3)
Install two screws (16) and nuts (17) on
straps (18) and tighten until air cleaner
housing (4) is secured.
d.
Installation.
(1)
Install air filter housing (4) on forklift (15)
with two washers (14) and screws (13).
(2)
Install hose (11) on air cleaner housing (4)
and tube (12) with two clamps (10).
(3)
Install fitting (9) on air cleaner housing (4).
(4)
Install hose (8) on fitting (9).
4-8
|