TM 10-3930-669-20
b.
Cleaning/lnspection.
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves; use
only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not breathe
vapors. Keep away from heat or flame. Never smoke when using solvent; the flashpoint for type
I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts with drycleaning solvent.
(2)
Do not allow drycleaning solvent to come in contact with rubber parts.
(3)
Inspect parts for breaks, cracks, burrs, and sharp edges.
(4)
Replace all damaged parts.
c.
Installation.
(1)
Install seal (5) on fuel supply pump (3).
(2)
Install fuel supply pump (3) on injection
pump (4) with three lock washers (2) and
nuts (1). Tighten nuts to 7 lb-ft (10 Nm).
NOTE
Follow-on Maintenance:
Install cab (Para 15-2).
Remove wheel chocks (TM 10-3930-
669-10).
END OF TASK
4-5
|