TM 10-3930-669-20
(11)
Place adapter (38) in a soft-jawed vise.
(12)
Remove fitting (36) from fitting (51).
(13)
Remove fitting (51) from adapter (38).
(14)
Remove fitting (37) from adapter (38).
(15)
Remove adapter (38) from vise.
c.
Cleaning/lnspection.
WARNING
Dry-cleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and gloves;
use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do not
breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for type I Dry-cleaning solvent is 100°F (38°C) and for type II is 138°F (50°C). Failure
to do so may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and medical
help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts eyes,
immediately flush eyes with water and get immediate medical attention.
(1)
Clean all parts with Dry-cleaning solvent.
(2)
Inspect hoses for holes, cracks, and deterioration.
(3)
Inspect oil filter adapter for cracks and damage.
(4)
Notify supervisor of any damage.
d.
Assembly.
(1)
Place adapter (38) in a soft-jawed vise.
(2)
Install two fittings (37 and 51) on adapter
(38).
(3)
Install fitting (36) on fitting (51).
(4)
Remove adapter (38) from vise.
3-17
|