2-32. STORAGE MAINTENANCE PROCEDURES (CONT.) .
f.
Tilt the mast assembly forward to collapse both tilt cylinders.
g.
Position the sideshift front end to the right side of the forklift. One shift cylinder will collapse with the
second extended.
h.
Remove batteries (Para 7-48).
(1)
Brush and clean battery cable terminal ends if corrosion is present. Coat with a thin coat of grease.
CAUTION
Do not place battery on concrete floor; use wood as an insulator. Failure to comply may result in
damage to the battery.
(2)
Place battery where it may be periodically serviced and charged.
i.
Perform complete lubrication in accordance with LO 10-3930-669-12.
WARNING
Drycleaning solvent (P-D-680) is TOXIC and flammable. Wear protective goggles and
gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and clothes; and do
not breathe vapors. Keep away from heat or flame. Never smoke when using solvent; the
flashpoint for type I drycleaning solvent is 100°F (38°C) and for type II is 138°F (50°C).
Failure to do so may result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
j.
Clean off the lubricating grease from exposed metal side shift channels or guides using drycleaning solvent
(P-D-680). Spray all exposed side shift surfaces with a long-term corrosion inhibitor.
k.
Protect the exposed shift cylinder rod and chains by spraying corrosion inhibitor.
I.
Protect mast assembly chains, carriage tips, and any other exposed metal parts by spraying with corrosion
inhibitor.
2-496
|