TM 10-3930-669-20
2-26. GENERAL ASSEMBLY INSTRUCTIONS (CONT) .
WARNING
On direct contact, uncured silicon sealant irritates eyes. In case of contact, flush eyes with water
and seek medical attention. In case of skin contact, wipe off and flush with water.
g.
Silicone Sealant. Silicone sealant is often used instead of a gasket to seal mating parts. The mating parts
must be clean, dry, and free of oil or grease for proper adhesion. After silicone sealant has been applied, the mating
parts must be assembled immediately. Silicone sealant starts to set-up in 15 minutes and takes 24 hours to completely
set. Excess silicone sealant should be removed after assembling the mating parts.
h.
Gaskets. Remove all traces of previous gasket and sealant before installing new gasket.
2-27. GENERAL INSTALLATION INSTRUCTIONS .
a.
Preparation. When unpacking items, remove all packing material, barrier paper, tape, plastic, plastic bags,
protective caps, and protective grease coatings. Handle and store removed components carefully.
CAUTION
Use sealing compound sparingly and only on threads. Do not apply compound to hose
connections. Damage to equipment may result.
b.
Sealing Compounds. Use sealing compounds as required in each maintenance task.
c.
Torquing. Tighten screws as required in Appendix E or in each maintenance task.
d.
Identification Tags. Use identification tags and other identifying markings to ensure hoses, tubes, lines, and
electrical wiring are installed and connected correctly.
e.
Hoses, Air Lines, and Wiring. After installing hoses, air lines, and wiring, ensure that they do not contact
moving parts or components edges. Secure in place, out of the way, with cable ties and cushion clips.
f.
Filters. Install Spin-on Filters hand tight. Once filter stops, turn 1/3.
2-28. ADJUSTMENT.
Make changes to equipment pressures, settings, and positions only as required in each maintenance task. Adjustments
will bring equipment into proper operating condition.
2-494
|