TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Remove engine ventilation panel (Para 6-2). (2) Set multimeter select switch to VOLTS DC. (3) Connect positive (+) multimeter lead on wire 23 at starter solenoid. (4) Connect negative (-) multimeter lead to a known good ground. (5) Start engine (TM 10-3930-669-10). (a) If there are not 22 to 24 vdc present, perform Step (6) below and go to Step 7 of this Fault. (b) If there are 22 to 24 vdc present, perform Step (6) below and go to Step 3 of this Fault. (6) Shut down engine. VOLTAGE TEST (1) Set multimeter select switch to VOLTS DC. (2) Connect positive (+) multimeter lead to starter solenoid input terminal. (3) Connect negative (-) multimeter lead to a known good ground. (a) If there are not 22 to 24 vdc present, replace shunt to starter cable (Para 7-53). (b) If there are 22 to 24 vdc present, shunt to starter is OK. 2-17