TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a direct
short may result in instant heating of tools, damage to equipment, and injury or death to personnel.
VOLTAGE TEST
(1) Remove engine ventilation panel
(Para 6-2).
(2) Set multimeter select switch to
VOLTS DC.
(3) Connect positive (+) multimeter
lead on wire 23 at starter solenoid.
(4) Connect negative (-) multimeter
lead to a known good ground.
(5) Start engine (TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, perform Step (6)
below and go to Step 7 of this
Fault.
(b) If there are 22 to 24 vdc
present, perform Step (6)
below and go to Step 3 of this
Fault.
(6) Shut down engine.
VOLTAGE TEST
(1) Set multimeter select switch to
VOLTS DC.
(2) Connect positive (+) multimeter
lead to starter solenoid input
terminal.
(3) Connect negative (-) multimeter
lead to a known good ground.
(a) If there are not 22 to 24 vdc
present, replace shunt to starter
cable (Para 7-53).
(b) If there are 22 to 24 vdc
present, shunt to starter is OK.
2-17
|