TM 10-3930-669-20 CONTINUITY TEST (1) Set    multimeter    select    switch    to OHMS. (2) Check  continuity  between  relay  R8, terminal    87    and    connector    P18, terminal 1. (a) If  there  is  no  continuity,  repair wire 74 (see schematic Appendix F). (b) If   there   is   continuity,   replace relay RB. (3) Install relay R8 (Para 7-33). (4) Connect  connector  P18  on  axle  oil pump. (5) Install oil filter tray (Para 4-13). 2-373