TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a
direct short may result in instant heating of tools, damage to equipment, and injury or death to
personnel.
VOLTAGE TEST
(1)
Remove oil filter tray (Para 4-13). Do
not disconnect hoses or wires.
(2)
Disconnect connector P18 from axle
oil pump connector.
(3)
Set
multimeter
select
switch
to
VOLTS DC.
(4)
Connect positive (+) multimeter lead
to connector P18, terminal 1.
(5)
Connect negative (-) multimeter lead
to a known good ground.
(6)
Turn Main power switch to the ON
position (TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, perform Step (7) below
and go to Step 18 of this Fault.
(b) If there are 22 to 24 vdc present,
perform Step (7) below and go to
Step 17 of this Fault.
(7)
Turn Main power switch to the OFF
position.
2-363
|