TM 10-3930-669-20
CONTINUITY TEST
(1) Set multimeter select switch to OHMS.
(2) Check continuity between relay R3,
terminal 85 and a known good ground.
(a) If there is no continuity, repair relay
R3 ground wire (see schematic
Appendix F).
(b) If there is continuity, replace relay
R3.
(3) Install relay R3 (Para 7-33).
VERIFY REPAIR
(1) Set transmission control lever in forward
position (TM 10-3930-669-10).
(2) Start engine (TM 10-3930-669-10).
(a) If
engine
does
not
start
with
transmission engaged, go to Step
(3) below.
(b) If engine starts with transmission
engaged,
fault
not
corrected.
Perform Steps (5) and (6) below
and repeat procedure and notify
Supervisor.
(3) Set transmission control lever in reverse
position.
(4) Start engine.
(a) If
engine
does
not
start
with
transmission
engaged,
fault
corrected. Perform Steps (5) and
(6) below.
(b) If engine starts with transmission
engaged,
fault
not
corrected.
Perform Steps (5) and (6) below
and repeat procedure and notify
Supervisor.
(5) Set transmission control lever in neutral
position.
(6) Shut down engine.
2-281
|