TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a
direct short may result in instant heating of tools, damage to equipment, and injury or death to
personnel.
VOLTAGE TEST
(1) Remove floor plate (Para 15-12).
(2) Disconnect
connector
P11
from
transmission control connector.
(3) Set multimeter select switch to VOLTS
DC.
(4) Connect positive (+) multimeter lead to
connector P11, terminal 3.
(5) Connect negative (-) multimeter lead to
a known good ground.
(6) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(7) Set engine switch to ignition position
(TM 10-3930-669-10).
(8) Set transmission control lever to forward
position (TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, perform Steps (9) through
(12) below and go to Step 2 of this
Fault.
(b) If there are 22 to 24 vdc present,
forward control solenoid is faulty.
Perform Steps (9) through (12)
below and Notify DS Maintenance.
(9) Set transmission control lever to neutral
position.
(10) Set engine switch to off position.
(11) Set MAIN POWER switch to OFF
position.
(12) Install floor plate (Para 15-12).
2-251
|