TM 10-3930-669-20
20. BROKEN BELT BUZZER AND INDICATOR DO NOT OPERATE (CONT).
KNOWN INFO
Belt broken.
24 vdc circuits operate.
Wire 6 OK.
POSSIBLE PROBLEMS
Belt sensor faulty.
Wire 8 faulty.
TEST OPTIONS
Continuity test.
STE/ICE-R #91.
REASON FOR QUESTION
If continuity is not present, belt
sensor is faulty.
¬
2-246
|