TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Set multimeter select switch to VOLTS DC. (2) Connect positive (+) multimeter lead to glow plug relay R6, terminal 30 cavity. (3) Connect negative (-) multimeter lead to a known good ground. (4) Set MAIN POWER switch to ON position (TM 10-3930-669-10). (a) If there are not 22 to 24 vdc present, perform Step (5) below, repair wire 7 (see schematic Appendix F) and go to Step 9 of this fault. (b) If there are 22 to 24 vdc present, wire 7 is OK. (5) Set MAIN POWER switch to OFF position. CONTINUITY TEST (1) Ground wire 30 glow plug terminal. (2) Set multimeter select switch to OHMS. (3) Check continuity between relay R6, terminal 87 and glow plug terminal. (a) If there is no continuity, repair wire 30 (see schematic Appendix F). (b) If there is continuity, replace relay R6. (4) Install relay R6 (Para 7-3). (5) Install engine ventilation panel (Para 6-2). 2-239