TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Remove engine ventilation panel (Para 6-2). (2) Remove relay R6 (Para 7-33). (3) Set multimrneter select switch to VOLTS DC. (4) Connect positive (+) multimeter lead to glow plug relay R6, terminal 86 cavity. (5) Connect negative (-) multimeter lead to a known good ground. (6) Set MAIN POWER switch to ON position (TM 10-3930-669-10). (7) Set engine switch to ignition position (TM 10-3930-669-10). (8) Depress glow plug switch (TM 10-3930-669-10). (a) If there are not 22 to 24 vdc present, perform Steps (9) and (10) below and go to Step 9 of this Fault. (b) If there are 22 to 24 vdc present, perform Steps (9) and (10) below and go to Step 6 of this Fault. (9) Set engine switch to off position. (10)    Set MAIN POWER switch to OFF position. CONTINUITY TEST (1) Set multimeter select switch to OHMS. (2) Check continuity between relay R6, terminal 85 cavity and a known good ground. (a) If there is no continuity, replace relay R6 ground wire (See schematic Appendix F). (b) If there is continuity, relay R6 ground wire is OK. 2-237