TM 10-3930-669-20 WARNING Remove all jewelry such as rings, dog tags, bracelets, etc.  If jewelry contacts battery terminal, a direct short may result in instant heating of tools, damage to equipment, and injury or death to personnel. VOLTAGE TEST (1) Remove instrument panel (Para 7-8). (2) Disconnect indicator wire 30 from connector. (3) Set multimeter select switch to VOLTS DC. (4) Connect positive (+) multimeter lead to indicator wire 30 terminal. (5) Connect negative (-) multimeter lead to a known good ground. (6) Set MAIN POWER switch to ON position (TM 10-3930-669-10). (7) Set engine switch to ignition position (TM 10-3930-669-10). (8) Depress glow plug switch (TM 10-3930-669-10). (a) If there are not 22 to 24 vdc present, perform Steps (9) through (11), repair wire 30 (see schematic Appendix F) and go to Step 5 of this fault. (b) If there are 22 to 24 vdc present, perform Steps (9) and (10) below and go to Step 4 of this fault. (9) Set engine switch to off position. (10)    Set MAIN POWER switch to OFF position. (11)    Connect indicator wire 30 on connector. 2-233