TM 10-3930-669-20 2-14.  ELECTRICAL SYSTEM TROUBLESHOOTING (CONT). 16.  FAN(S) DOES NOT OPERATE. INITIAL SETUP Tools and Special Tools Tool Kit, General Mechanic's: Automotive (Item 1, Appendix B) Multimeter (Item 2, Appendix B) STE/ICE-R (Optional) (Item 14, Appendix B) References TM 10-3930-669-10 Equipment Condition Engine OFF (TM 10-3930-669-10) MAIN POWER switch OFF (TM 10-3930-669-10) Parking brake applied (TM 10-3930-669-10) Wheels chocked (TM 10-3930-669-10) KNOWN INFO Cab lights operate. POSSIBLE PROBLEMS Fan motor faulty. Wire 36 faulty. Ground wire 13 faulty. TEST OPTIONS Voltage test. STE/ICE-R #89. REASON FOR QUESTION If 22 to 24 vdc are not present, wire 36 is faulty.  If wire 36 is OK, fan motor is faulty. 2-214

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business