TM 10-3930-69-20
15. HORN DOES NOT OPERATE (CONT).
KNOWN INFO
24 vdc circuits operate.
Fuse 5 OK.
POSSIBLE PROBLEMS
Wire 27 faulty.
Horn faulty.
Horn contact plate faulty.
Wire 21 faulty.
KNOWN INFO
24 vdc circuits operate.
Fuse 5 OK.
Wire 27 OK.
POSSIBLE PROBLEMS
Horn faulty.
Horn contact plate faulty.
Wire 21 faulty.
TEST OPTIONS
Voltage test.
STEACE-R #89.
REASON FOR QUESTION
This question eliminates a
possible problem or group of
possible problems determining
where troubleshooting
continues.
TEST OPTIONS
Continuity test.
STE/ICE-R #91.
REASON FOR QUESTION
If continuity is not present, fault
is ground circuit. If continuity is
present, horn is faulty.
2-208
|