TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a
direct short may result in instant heating of tools, damage to equipment, and injury or death to
personnel.
VOLTAGE TEST
(1) Set multimeter select switch to VOLTS
DC.
(2) Connect positive (+) multimeter lead to
hour meter, terminal (+).
(3) Connect negative (-) multimeter lead to
a known good ground.
(4) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(5) Set engine switch to ignition position
(TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present,
repair
wire
65
(See
schematic Appendix F).
(b) If there are 22 to 24 vdc present,
wire 65 is OK.
(6) Set engine switch to off position.
(7) Set MAIN POWER switch to OFF
position.
CONTINUITY TEST
(1) Set multimeter select switch to OHMS.
(2) Check continuity between hour meter,
terminal (-) and a known good ground.
(a) If there is no continuity, replace
hour meter ground wire.
(b) If there is continuity, replace hour
meter (Para 7-10).
(3) Install instrument panel (Para 7-8).
2-157
|