TM 10-3930-669-20
WARNING
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry contacts battery terminal, a
direct short may result in instant heating of tools, damage to equipment, and injury or death to
personnel.
VOLTAGE TEST
(1) Remove instrument panel (Para 7-8).
(2) Set multimeter select switch to VOLTS
DC.
(3) Connect positive (+) multimeter lead to
transmission
temperature
gauge,
terminal I.
(4) Connect negative (-) multimeter lead to
a known good ground.
(5) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(6) Set engine switch to ignition position
(TM 10-3930-669-10).
(a) If there are not 22 to 24 vdc
present, repair gauge wire 5 (see
schematic Appendix F) and go to
Step 3 of this Fault.
(b) If there are 22 to 24 vdc present,
gauge wire 5 is OK.
(7) Set MAIN POWER switch to OFF
position.
(8) Set engine switch to off position.
CONTINUITY TEST
(1) Set multimeter select switch to OHMS.
(2) Check continuity between transmission
temperature gauge, terminal G and a
known good ground.
(a) If there is no continuity, repair
gauge ground wire (see schematic
Appendix F).
(b) If there is continuity, gauge ground
wire is OK.
2-147
|