TM 10-3930-669-20 CONTINUITY TEST (1)   Set multimeter select switch to OHMS. (2)   Disconnect    connector    P12    from    fuel sender connector. (3)   Check   continuity   between   fuel   gauge, terminal S and connector P12, terminal 1. (a)   If    there    is    no    continuity,    repair sensor     wire     18     (see     schematic Appendix F). (b)   If   there   is   continuity,   replace   fuel gauge  (Para  7-9)  and  go  to  Step  5 of this Fault. (4)   Install instrument panel (Para 7-8). VERIFY REPAIR (1)   Start engine (TM 10-3930669-10). (2)   Observe fuel gauge(s). (a)   If    gauge    does    not    give    correct reading, fault not corrected. Perform   Step   (3)   below.      Repeat procedure and notify Supervisor. (b)   If gauge gives correct reading, fault corrected. (3)   Shut down engine. 2-143