TM 10-3930-669-20
CONTINUITY TEST
(1) Set multimeter select switch to OHMS.
(2) Disconnect connector P12 from fuel
sender connector.
(3) Check continuity between fuel gauge,
terminal S and connector P12, terminal
1.
(a) If there is no continuity, repair
sensor wire 18 (see schematic
Appendix F).
(b) If there is continuity, replace fuel
gauge (Para 7-9) and go to Step 5
of this Fault.
(4) Install instrument panel (Para 7-8).
VERIFY REPAIR
(1) Start engine (TM 10-3930669-10).
(2) Observe fuel gauge(s).
(a) If gauge does not give correct
reading,
fault
not
corrected.
Perform Step (3) below. Repeat
procedure and notify Supervisor.
(b) If gauge gives correct reading, fault
corrected.
(3) Shut down engine.
2-143
|