TM 10-3930-669-20
CONTINUITY TEST
(1) Ground connector P12, terminal 1.
(2) Set MAIN POWER switch to ON
position (TM 10-3930-669-10).
(3) Set engine switch to ignition position
(TM 10-3930-669-10).
(4) Observe gauge needle for reading.
(a) If gauge does not have a full scale
deflection,
perform
Steps
(5)
through (7) and go to Step 2 of this
Fault.
(b) If gauge has a full scale deflection,
perform Steps (6) through (7) below
replace fuel sensor (Para 7-35).
(5) Connect connector P12 on fuel level
sender connector.
(6) Set engine switch to off position.
(7) Set MAIN POWER switch to OFF
position.
2-139
|