TM 10-3930-669-20
1.
ALL 24 VDC CIRCUITS DO NOT OPERATE (CONT).
KNOWN INFO
Main disconnect switch is on.
Engine cranks but does not
stay running.
Wire 34 OK.
POSSIBLE PROBLEMS
Relay R2 ground wire faulty.
Wire 7 faulty.
Wire 26 faulty.
Relay R2 faulty
Engine switch faulty.
KNOWN INFO
Main disconnect switch is on.
Engine cranks but does not
stay running.
Wire 34 OK.
Relay R2 ground wire OK.
POSSIBLE PROBLEMS
Wire 7 faulty.
Wire 26 faulty.
Relay R2 faulty.
Engine switch faulty.
TEST OPTIONS
Continuity test.
STE/ICE-R #91.
REASON FOR QUESTION
If continuity is not present,
relay R2 ground wire is faulty.
TEST OPTIONS
Voltage test.
STE/ICE-R #89.
REASON FOR QUESTION
If 22 to 24 vdc are not present,
wire 7 is faulty.
¬
¬