TM 10-3930-669-10
Table 2-3. Operator Preventive Maintenance Checks and Services - CONT.
Location
Item
Interval
Item to
Procedure
Not Fully Mission
No.
Check/Service
Capable If:
DAILY-
INTERIOR-
Continued
Continued
20
During
Belt, Buzzer and
Monitor broken belt warning light and
Warning light or buzzer
Warning Lights
listen for warning buzzer during
indicates a malfunction
operation.
and corrective action by
the operator does not
correct the problem.
EXTERIOR
21
During
Work Lights and
Check for proper operation. Notify Unit
Stop/Taillight
Maintenance.
2-21
|