TM 10-3930-664-24
NOTE
Handle (12) is removed when selector
valve is removed from forklift. If
reinstalled, removal is required.
5.
Remove handle (12) from valve spool (15) by
removing cotter pin (13) and handle pin (14).
Discard cotter pin.
6.
Carefully slide valve spool (15) out of valve
housing (2).
CAUTION
Use care when removing spool seals
(16) to prevent damage to spool surface.
Note position of seals before removing
to aid in installation.
7.
Remove spool seals (16) from valve spool (15)
using a small tip screwdriver.
8.
Remove handle bracket (17) from valve housing
(2) by removing screws (18).
B. CLEANING
Clean selector valve components in accordance with
paragraph 1-24.
C. INSPECTION
Inspect selector valve components in accordance
with paragraph 1-24.
D. REPAIR
Repair of the selector valve consists of removal and
replacement
of
defective,
deformed,
or
damaged
components.
E. ASSEMBLY
1.
Install handle bracket (17) onto valve housing (2)
using screws (18).
3-160
|