TM 10-3930-664-24
10. Carefully mate rotor and drive end shield (6) to ring
end shield (7).
11. To obtain proper running alignment, insert three
0.008 inch feeler gages between stator and rotor.
Install four screws (8) and tighten in a criss-cross
pattern.
12. Install transistor regulator (1)
onto alternator
(2) using screws (3). Install suppression capacitor
(4) using screw (5).
13. Plug connector on capacitor (4) onto B+ terminal.
G.
TESTING
1.
Install alternator in test set-up as shown in figure.
Set regulated voltage on test set-up to 26 volts.
CAUTION
Connection
between
alternator
and
battery must not be disconnected when
alternator is running. Semiconductors
and regulator may be destroyed.
2.
Operate alternator at 2000 rpm for 2 minutes to
bring alternator to normal operating temperature.
3.
Reduce alternator speed to 1750 rpm.
4.
Adjust loading resistor until a reading of 10 amps is
achieved. Indicated voltage shall be 26 volts.
5.
Raise alternator speed to 2750 rpm.
6.
Adjust loading resistor until a reading of 30 amps is
achieved. Indicated voltage shall be 26 volts.
7.
Raise alternator speed to 6000 rpm.
3-94
|