Section XXII. NON-ELECTRICAL GAGE MAINTENANCE
2-165.
HYDRAULIC
RESERVOIR
SIGHT
GAGE
REPLACEMENT
This task covers: Removal, Cleaning, Inspection, and
Installation
INITIAL SETUP:
Tools and Test Equipment:
General Mechanics Tool Kit (1, App. E)
References:
LO 10-3930664-12
A.
REMOVAL
1.
Remove cleanout cover (1) from hydraulic
reservoir (6) by removing screw (2) and washer
(3).
2.
Remove and inspect gasket (4). Replace if
damaged.
CAUTION
Do not remove hollow bolts (7) from
sight gage (5). Gage -rings will be
damaged.
NOTE
Hydraulic
reservoir
sight
gage
and
attaching hardware are supplied as an
assembly kit. If any component is
damaged during removal, replacement
of the entire assembly will be required.
3.
Remove hydraulic reservoir sight gage (5) from
hydraulic reservoir (6) by removing loosening
hollow bolts (7) and removing washers (8) and
nuts (9).
B.
CLEANING
Clean hydraulic reservoir sight gage in accordance with
paragraph
1-24.