TM 10-3930-664-24
4.
INSTALL ELBOWS (89), FITTING (112), AND
NEW O-RINGS (113, 114) INTO SEQUENCE
VALVE (95).
5.
INSTALL SEQUENCE VALVE (95) USING
SCREWS (110) AND LOCKWASHERS (111).
NOTE
When installing a new diverter valve,
remove diverter valve knob from old
valve and use on new valve. Apply
loctite to threads on spool of new
diverter valve and install knob onto
spool.
6.
INSTALL FITTINGS (105), TEE (106), AND
ELBOW (107) ONTO DIVERTER VALVE (92).
INSTALL DIVERTER VALVE ONTO BRACKET
(108) USING SCREWS (109).
7.
CONNECT HOSE ASSEMBLIES (96, 99) WITH
FITTINGS AND FUSES.
a.
Install elbows (103) and new O-rings
(104) into bottom of main lift cylinders
(80).
b.
Install fittings (102) onto elbows (103).
c.
Install tee (98), fitting (100), and
velocity fuses (101) onto fittings (102).
d.
Connect hose assembly (99) to tee (98)
and fitting (100).
e.
Install elbow (97) onto tee (98).
f.
Connect hose assembly (96) to elbow
(97) and diverter valve (92).
2-429
|