TM 10-3930664-24 2-144.  DEFROSTER FAN ASSEMBLY REPLACEMENT (MODEL MHE-271 ONLY) This task covers: Removal, Cleaning, Inspection, and Installation INITIAL SETUP: Tools and Test Equipment: Equipment Condition: General Mechanics Tool Kit (1, App.  E) Batteries disconnected (para.  2-78) A.  REMOVAL WARNING Electrical    shock    hazard.        Disconnect battery   ground   cable   or   power   source prior to working on electrical components.    Failure   to   heed   warning could  cause  shock,  injury  or  death.    If electrical  shock  occurs,  administer  first aid and seek medical assistance immediately. 1 Tag and disconnect electrical wiring from defroster fans (1, 2). 2 Remove  front  defroster  fan  (1)  from  bracket  on driver side panel (3) by removing screws (4) and nuts (5). 3 Remove rear defroster fan (2) from right window frame (7) by removing screws (8) and nuts (9). B.  CLEANING Clean defroster fans in accordance with paragraph 1-24. 2-382