TM 10-3930-664-24
2-90. SLAVE RECEPTACLE REPLACEMENT
This task covers: Removal, Cleaning, Inspection, and Installation
INITIAL SETUP:
Tools and Test Equipment:
Materials / Parts:
General Mechanics Tool Kit (1, App. E)
Loctite 242 (20, App. C)
A. REMOVAL
WARNING
Electrical shock hazard. Disconnect battery ground
cable or power source prior to working on electrical
components. Failure to heed warning could cause
shock, injury or death. If electrical shock occurs,
administer first aid and seek medical assistance
immediately.
1.
Remove top transmission cover (1) by removing
nine screws (2) and washers (3).
2.
Tag electrical wiring. Remove cables and wiring
from slave receptacle (5) by removing screws
(6).
3.
Remove cap (4). Remove slave receptacle (5)
from side transmission cover by removing
screws (7) and nuts (8).
B. CLEANING
Clean slave receptacle in accordance with paragraph 1-
24.
C. INSPECTION
Inspect
receptacle
and
related
components
in
accordance with paragraph 1-24.
2-256
|