TM 103930-664-24
C. INSPECTION
Inspect cables for cuts, tears, or damage. Inspect cable
lugs for corrosion.
D. INSTALLATION
1.
CONNECT BATTERY CABLES (3, 4, 5).
a. Install crossover cable (5) onto positive and
negative battery terminals and secure by
tightening cable lug nuts.
b. Install positive cable (4, RED) onto positive
battery terminal and secure by tightening
cable lug nut.
c. Install ground cable (3, BLACK) onto negative
battery terminal and secure by tightening
cable lug nut.
2.
INSTALL BATTERY BOX LID (1) AND TURN
LID LATCHES (2) TO SECURE.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
2-226
|