TM 10-3930-664-24
2.
INSTALL PRESSURE TRANSDUCER (22).
a.
Install adapter (27). Install pressure
transducer (26) onto adapter.
b.
Connect pressure transducer electrical wiring
(25).
3.
INSTALL RESISTOR ASSEMBLY (19) AND
ALTERNATE FUEL SHUTOFF SWITCH (21) ONTO
DCA PLATE (10).
a.
Install alternate fuel shutoff switch (21) onto DCA
plate (10) using attaching nut.
b.
Connect electrical wiring to resistor assembly
(19). Connect wires (22, 23, 24) to alternate fuel
shutoff switch (21).
c.
Install resistor assembly (19) onto DCA plate
(10) using screws (20).
4.
INSTALL DIFFERENTIAL PRESSURE SWITCH
(9) ONTO DCA PLATE (10).
a.
Install fittings (14) onto differential pressure
switch (9). Install clamps (15).
b.
Align spacers (16) with holes in DCA plate (10).
Secure differential pressure switch (9) onto DCA
plate using screws (17) and lockwashers (18).
c.
Connect hose assemblies (12, 13) to fittings
(14).
d.
Connect differential pressure switch electrical
wiring (11).
5.
APPLY LOCTITE TO SCREWS (7). INSTALL
TRANSMISSION COVER TOP (6) USING NINE
SCREWS (7) AND WASHERS (8).
2-188
|