TM 10-3930-664-24
7.
REMOVE DCA SHUNT (41) FROM FORKLIFT
FLOOR PLATE.
a.Tag and disconnect electrical cable (28) and wiring
(29) from DCA shunt (41) by removing screw
(30) and lockwasher (31).
b.Tag and disconnect electrical cable (32) and wiring
(33) from DCA shunt (41) by removing screw
(34) and lockwasher (35).
c.Tag and disconnect electrical wiring (36, 37) from
DCA shunt (41) by removing screws (38),
lockwashers (39), and washers (40).
d.Remove DCA shunt (41) from forklift floor plate by
removing screws (42), lockwashers (43), and
locknuts (44).
B
CLEANING
Clean STE/ICE electrical components in accordance
with paragraph 1-24.
C.
INSPECTION
Inspect STE/ICE electrical components and related parts
in accordance with paragraph 1-24.
D.
INSTALLATION
1.
INSTALL DCA SHUNT (41) ONTO FORKLIFT
FLOOR PLATE.
a.
Install DCA shunt (41) onto forklift floor plate
using screws (42), lockwashers (43), and
locknuts (44).
b.
Connect electrical wiring (36, 37) to DCA shunt
(41) using screws (38), lockwashers (39), and
washers (40).
c.
Connect electrical cable (32) and wire (33) to
DCA
shunt
(41)
using
screw
(34)
and
lockwasher (35).
d.
Connect electrical cable (28) and wire (29) to
DCA
shunt
(41)
using
screw
(30)
and
lockwasher (31).