TM 10-3930-664-24
2-60. CIRCUIT BREAKER REPLACEMENT
This task covers: Removal, Cleaning, Inspection, and Installation
INITIAL SETUP:
Tools and Test Equipment:
Equipment Condition:
General Mechanics Tool Kit (1, App. E)
Batteries disconnected (para. 2-78)
A. REMOVAL
WARNING
Electrical shock hazard. Disconnect
battery ground cable or power source
prior
to
working
on
electrical
components. Failure to heed warning
could cause shock, injury or death. If
electrical shock occurs, administer
first aid and seek medical assistance
immediately.
1.
TAG AND DISCONNECT ELECTRICAL WIRES
FROM CIRCUIT BREAKERS (1, 2, 3).
a.
Disconnect red wire (4) from short stud on
circuit breaker (1). Disconnect red wire (5)
from long stud.
b.
Disconnect blue wire (6) from short stud
on circuit breaker (2). Disconnect
orange (7), purple (8), yellow (9), and
brown (10) wires from long stud.
c.
Disconnect green wire (11) and two blue
wires (12, 13) from short stud on circuit
breaker (3). Disconnect purple wire (14)
from long stud.
2.
REMOVE CIRCUIT BREAKERS (1, 2, 3) FROM
INSTRUMENT
PANEL
BY
REMOVING
SCREWS (15) AND NUTS (16).
2-182
|