TM 10-3930-664-24 2-40.  ETHER CYLINDER REPLACEMENT This task covers: Removal and Installation INITIAL SETUP: Tools and Test Equipment: General Mechanics Tool Kit (1, App.  E) A.  REMOVAL 1. Open    transmission    access    door    (1)    by  rotating handle (2) left. WARNING Starting    fluid    is    toxic    and    highly flammable. Container is pressurized.      Never      heat   container and  never  discharge  starting  fluid  in confined areas or near an open flame. Failure to comply can result in severe injury. 2. Loosen clamp (3) until it is completely disconnected. Remove ether canister (4) from injector assembly (5) by turning left. B.  INSTALLATION 1. Install  new  ether  canister  (4)  into  injector  assembly (5) by turning right.  Secure by tightening clamp (3). 2. Close  transmission  access  door  (1)  and  secure  by rotating handle (2). FOLLOW-ON MAINTENANCE: None END OF TASK 2-134

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business