TM 10-3930-664-24
2-32. EVACUATOR VALVE REPLACEMENT
This task covers: Removal, Cleaning, Inspection, and Installation
INITIAL SETUP:
Tools and Test Equipment:
General Mechanics Tool Kit (1, App. E)
A. REMOVAL
1. Open
access
door
(1)
located
on
left
side
transmission
cover
by
rotating
handle
(2)
counterclockwise.
2. Remove evacuator valve (4) from air cleaner (5) by
loosening clamp (3).
B. CLEANING
Clean evacuator valve in accordance with paragraph 1-
24.
C. INSPECTION
Inspect evacuator valve for obvious damage. Replace if
damaged.
D. INSTALLATION
1. Install evacuator valve (4) onto air cleaner (5) and
secure using clamp (3).
2. Close access door (1) and secure by rotating handle
(2) clockwise until fully engaged.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
2-115
|